Topping up fresh water in an aquaponic system: reliability of supply sources

From Triple Performance

The success of an aquaponic system obviously relies on a fundamental element: water. Although its requirement is very low, its quality plays a crucial role in creating a healthy environment for fish, bacteria, and plants from the moment it enters this ecosystem. This article explores the criteria for high-quality new water, necessary for the proper start-up and maintenance of an aquaponic system.

Description

Sources / Origins

Whether it comes from rain, a municipal network, or a well, the parameters of new water must be carefully monitored.

Rainwater, although free and easily storable, shows great variability in quality depending on the seasons and location. It is therefore preferable not to rely exclusively on this source for supplying new water to the system. Moreover, rainwater collected from roofs may contain traces of pesticides or other undesirable residues (nearby industry, incinerator, etc.) and carries a high risk of accumulation and cocktail effects in a very closed system.

Network water, on the other hand, often contains chlorine and chloramine, purifying agents that are unfortunately harmful to fish. It is strongly recommended to dechlorinate this water before introducing it into the system, using techniques such as degassing or specific filters (activated carbon, UV, etc.).

The quality of well water varies considerably depending on the location and depth of the well. A thorough analysis of this water is essential to detect possible contaminants and assess its compatibility with the aquaponic system. To ensure the quality of the extracted water and the purification or even potabilization devices to be planned (if used for processing), it is recommended to consult an accredited laboratory.

Analyses / Parameters

To carry out these analyses, we recommend contacting one of the many accredited laboratories for sanitary water control. The analysis must cover three essential aspects: physico-chemical, bacteriological, and phytosanitary.

New water must comply with the tolerance thresholds of the species raised, the aquaculture being the most sensitive compartment for water quality in an aquaponic system. Note that tolerance thresholds vary greatly from one species to another, and they should then be verified in the recirculated water.

At the same time, it must also comply with the thresholds defined by the Water Framework Directive (WFD).

The following tables provide an indication of the values to be respected.

Regarding the physico-chemical aspect:

Parameters Tolerance thresholds in aquaculture (Sensitive species) New water thresholds / cat. A
pH 6.5 to 8.5 –
EC < 800 µS/cm 180 to 1000 µS/cm
T°C < 25°C –
COD (chemical oxygen demand) <60 mg/L –
Suspended solids <15 mg/L <25 mg/L
Turbidity <2 FNU –
Hardness 10 to 30 °f –
Hydrotimetric titre 10 to 30 °f –
Alkalimetric titre 10 to 30 °f –
Redox potential +200 to +400 mV –
Dissolved CO2 <4 ppm –
Ammoniacal Nitrogen <1.5 mg/L <100 mg/L
Nitrites <0.3 mg/L <0.5 mg/L
Nitrates <100 mg/L <50 mg/L
Orthophosphates 40 to 60 mg/L 0.5 mg/L
Boron 1.5 mg/L
Potassium <10 mg/L 0.25 mg/L
Chlorides <0.003 mg/L –
Sulfates <50 mg/L 250 mg/L
Total Calcium 40 to 80 mg/L –
Magnesium <15 mg/L –
Sodium <30 mg/L 200 mg/L
Iron <0.05 mg/L <0.2 mg/L
Manganese <0.01 mg/L 0.05 mg/L
Lead – <10 µg/L
Mercury – <1 µg/L
Arsenic – <10 µg/L
Chromium – <25 µg/L
Nickel – <20 µg/L
Cyanide – <10 µg/L
Cadmium – <5 µg/L

Bacteriological analysis:

Parameters Thresholds in aquaculture New water thresholds / cat. A
Coliform bacteria 0 CFU/100mL 0 CFU/100mL
Escherichia coli <250 CFU/100mL 0 CFU/100mL
Intestinal enterococci 0 CFU/100mL 0 CFU/100mL
Salmonella 0 CFU/100mL 0 CFU/100mL
Anaerobic sulfate-reducing bacteria 0 CFU/100mL 0 CFU/100mL

Pesticide analysis:

Parameters Thresholds in aquaculture New water thresholds / cat. A
Phytosanitary products on dissolved fraction (e.g. Atrazine, Bromacil, Fluroxypyr…) – <0.1 µg/L
Glyphosates and derivatives (e.g. Glyphosate, AMPA…) – <0.1 µg/L
Multi-residue pesticides (e.g. Aldrin, Dieldrin, Heptachlor…) – <0.03 µg/L

As you have understood, incoming water, although required in very small quantities (often close to a daily input of 5 to 10% of the aquaculture volume), must be of impeccable quality. In closed-loop aquaponic systems, even small amounts of contaminants can accumulate over time, leading to harmful levels of particles and chemical substances. If pesticides or other pollutants enter the system, this could have disastrous consequences, not only on the productivity of your installation but also on the safety of products intended for end consumers.

Ensuring high-quality new water from the start is therefore crucial to avoid the formation of a toxic cocktail in your circuit water. By adopting rigorous monitoring practices and installing a water treatment device adapted to its origins and parameters, you protect the health of your fish and plants while ensuring safe and sustainable food production.